Building Code Clarified

Tag: door size

Panic or Fire Hardware 21-0

Panic or fire hardware, panic hardware at exit doors and/or out of other spaces is what this video covers. Panic hardware is used more times than it is required. It’s probably only required about half the time that I see it used. Only required in H occupancies or A or E spaces or occupancies, Where those occupancies are over 50 persons.

Exit / Exterior Walls 19-0


Ratings of exterior wall where an exit or horizontal exit meets the exterior wall. Picture wall is not required to be rated if the adjoining walls around the exit on the exterior are all 180 degrees or greater. Where the walls are less than 180° you joining walls shall be rated one hour 10 feet beyond the exit walls.

Door Encroachment 18-0

The distance a door is allowed to encroach into a hallway/corridor/exit way or path of travel out of the building. If a door opens on to a required exit width this video talks to how much it’s allowed to encroach. 7 inches is the max when the door is in its fully open position that it’s allowed to encroach. Otherwise if the door opens 180° the radius in which it opens that radius cannot encroach more than one half during that swing.

Exit inches for doors & stairs 7-0

This video focus on calculating exit inches required for doors and stairs. How they differ and how/why they are important to calculate.

I have taught myself something by producing this video. Never could figure out/remember was it .2 or .3 door or .2 or .3 for a stair. While putting this together I realized you come to a door before you come to stair. You come to .2 before you come to .3. —– .2 is for doors .3 is for stairs. I now no longer have to look this up every single time.